Devilbiss Five Liter Compact Oxygen Concentrator

Devilbiss Five Liter Compact Oxygen Concentrator

Brand/Manufacturer: DEVILBISS
Save UPTO
Authorized Retailer Badge
  • Prescription required
  • FSA Approved
  • Made in USA

Item 525DS & 525DS-Q is backorder and will be available to purchase once it is back in stock.

Devilbiss Five Liter Compact Oxygen Concentrator is updated with enhanced quality, durability, performance and simplicity in mind. This robust oxygen concentrator offers just the right balance of cool and quiet. The simplified, two-piece cabinet design allows for 15 percent typical sound quality improvement and an improved cooling process. It is paired with proven, patented DeVilbiss Turn-Down Technology, these improvements minimize wear on internal components and increase the life expectancy of the unit.

Item # Desc Pkg Price
525DS 5 Liter Oxygen Concentrator Each
$1069.99
$749.00
525DS-Q Ultra Quiet 5 Liter Oxygen Concentrator Each
$1427.19
$999.00

Features

  • Devilbiss Five Liter Compact Oxygen Concentrator has exclusive DeVilbiss OSD (Oxygen Sensing Device) that ensures patient safety and reliability for longer service intervals
  • Easy to assemble or disassemble two-piece cabinet for ease of maintenance
  • Readily accessible patient controls and protected cannula fitting
  • Recessed humidifier nook prevents damage
  • Lockable flow meter and noticeably quiet operation
  • Convenient top and side handles for easy transport
  • Accommodates up to a 50-foot cannula, 15.3 meters
  • Capacitor-powered alarms do not require a battery reducing service and maintenance
  • Alarm indicates:
    - Power failure
    - High or low pressure
    - Low oxygen
    - Service required light
  • Pressure-compensated flow meter to ensure accurate flow display
  • Pressure-relief valve and thermal protection on the compressor
  • Double insulated unit, two-prong plug
  • Flame-retardant cabinet
  • Patented DeVilbiss Turn-Down Technology:
    - Automatically turns down its flow cycle below 2-1/2 lpm, resulting in a 35% reduction in system pressure to reduce stress on compressor bearings and internal fittings
    - Energy-efficient design reduces power consumption by 15% or more compared with competitive designs to save patients an average of $100 in electricity costs annually
    - Minimizes wear on internal components thereby extending the life of concentrator
  • Click Here For Instruction Guide
  • NOTE: Prescription can be faxed to 1.203.616.2851 or emailed to [email protected]
  • Also available (separately):
    - Devilbliss Intake Filter Extended Life Replacement For Five Liter Compact Oxygen Concentrator(Code:MC44D-605)
    -
     Devilbiss Compressor Filter Replacement For Five Liter Compact Oxygen Concentrator(Code: 525D-622)
    -
     Devilbiss Final Bacteria Filter Replacement For Five Liter Compact Oxygen Concentrator(Code: PV5LD-651)

More Information

  • WARNING:
    - Oxygen causes rapid burning. Do not smoke while your oxygen concentrator is operating, or when you are near a person utilizing oxygen therapy.
    - Keep the oxygen concentrator and cannula at least 2 m (6.5 feet) from hot, sparking objects or naked sources of flame.
    - To ensure you receive the therapeutic amount of oxygen delivery according to your medical condition, 525 Oxygen Concentrator must:    1) Be used only after one or more settings have been individually determined or prescribed for you at your specific activity levels.
       2) Be used with the specific combination of parts and accessories that are in line with the specification of the concentrator manufacturer and that were used while your settings were determined.
    - For your safety, the oxygen concentrator must be used according to the prescription determined by your physician.
    - Equipment not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide.
    - This device contains electrical and/or electronic equipment. Follow local governing ordinances and recycling plans regarding disposal of device components.
    - Installation of 515LF-607 low output flow meter package will cause the low flow alarm to not work.
    - Use only water-based lotions or salves that are oxygen-compatible before and during oxygen therapy. Never use petroleum or oil-based lotions or salves to avoid the risk of fire and burns.
    - Do not lubricate fittings, connections, tubing, or other accessories of the oxygen concentrator to avoid the risk of fire and burns.
    - Use only spare parts recommended by the manufacturer to ensure proper function and to avoid the risk of fire and burns.
    - Use of this device at an altitude above 4000 meters or above a temperature of 35ËšC or greater than 95% relative humidity may affect the flow rate and the percentage of oxygen and consequently the quality of the therapy. Refer to specifications for details regarding parameters tested.
    - Oxygen makes it easier for a fire to start and spread. Do not leave the nasal cannula or mask on bed coverings or chair cushions if the oxygen concentrator is turned on but not in use, the oxygen will make the materials flammable. Turn the oxygen concentrator off when not in use to prevent oxygen enrichment.
    - If you feel discomfort or are experiencing a medical emergency while undergoing oxygen therapy, seek medical assistance immediately to avoid harm.
    - Geriatric, pediatric or any other patient unable to communicate discomfort can require additional monitoring and/or a distributed alarm system to convey the information about the discomfort and/or the medical urgency to the responsible caregiver to avoid harm.
    - Smoking during oxygen therapy is dangerous and is likely to result in facial burns or death. Do not allow smoking within the same room where the oxygen concentrator or any oxygen carrying accessories are located. If you intend to smoke, you must always turn the oxygen concentrator off, remove the cannula and leave the room where either the cannula or mask or the oxygen concentrator is located. If unable to leave the room, you must wait 10 minutes after you have turned the oxygen concentrator off before smoking.”
    - Open flames during oxygen therapy are dangerous and are likely to result in fire or death. Do not allow open flames within 2 m of the oxygen concentrator or any oxygen carrying accessories.”
    - The Device is classified as IPX0 which means it does not provide protection from water ingress. Keep the device dry. • Do not service or clean this device while in use with a Patient.
    - Under certain circumstances, oxygen therapy can be hazardous. Seek medical advice before using an oxygen concentrator. • When device is used under extreme operating conditions, the temperature near the exhaust vents on the bottom of the unit may reach 63˚C. Keep body parts a minimum of 32” away from this area.
    - Improper use of the power cord and plugs can cause a burn, fire, or other electric shock hazards. Do not use the unit if the power cord is damaged.
    - The DeVilbiss oxygen concentrators manufactured since July 1, 2012 are equipped with a fire mitigating outlet fitting that prevents propagation of fire into the unit. DeVilbiss oxygen concentrators manufactured prior to July 1, 2012 must be retrofitted by your provider with the fire mitigating outlet fitting.
    - In order to prevent a fire propagating from the patient through the cannula towards the unit, a means of protection should be located as close to the patient as practicable. Please contact your provider for this means of protection.
    - Before attempting any cleaning procedures, turn the unit “Off.”
  • CAUTION:
    - It is very important to follow your oxygen prescription. Do not increase or decrease the flow of oxygen – consult your physician.
    - To prevent product damage, do not attempt to operate the unit without the air filter or while the filter is still damp.
  • Patient/Caregiver Maintenance:
    - Clean and replace oxygen tubing, cannula/mask, and humidifier bottle (if used) according to the manufacturer’s instructions.
    - Cabinet air filter - clean weekly

Specification

Particulars

Dimensions

Outlet Pressure

8.5 PSIG (58.6 KPa)

Oxygen Purity

93% at 1 to 5 lpm (+/- 3%)

Power Consumption

310 Watts average
(275 Watts @ 2.5lpm and below)

Product Dimensions

24.5”H x 13.5”W x 12”D
(62.2cm x 34.2cm x 30.4cm)

Product Weight

36lbs (16.3kg)

Alarms

Audible and visual High/low pressure, low flow, low oxygen, power fail, Oxygen Sensing Device

Sound Level

48 dbA

Pressure Relief Valve

40 psig±5psig (276 kPa±34.5 kPa)

Electrical Rating

115V, 60Hz, 3.3amp

Storage Conditions

-40°C to 70°C, humidity range of 10% to 100%, including condensation

Delivery Rate (Lower delivery rates available for low flow applications)

0.5lpm to 5lpm

Maximum Recommended Flow (nominal outlet pressures of zero and 7kPa)

5lpm

Operating Voltage Range

97-127V, 60Hz

Oxygen Percentage

1-5 lpm=93%±3%

Warranty

5 year service life.

Customer Reviews

Please enter your and your friends email address below.
Fields marked with * are compulsory
 
*
*
*
*


Submit Cancel
The selected product information has been successfully emailed to your friend.

Thank you for using www.shopwoundcare.com