Drive MEDNEB Compressor Nebulizer

Drive MEDNEB Compressor Nebulizer

Brand/Manufacturer: DRIVE MEDICAL
Save UPTO
Authorized Retailer Badge
  • HyGiene Products
  • Non Returnable
  • FSA Approved

Drive MEDNEB Compressor Nebulizer is a compact medical device designed to efficiently deliver physician prescribed medication to the bronchial lung passages for the treatment of asthma, allergies, COPD, and other respiratory ailments. Intended for use by a single adult, pediatric, or infant patient.

Item # Desc Pkg Price
MQ5600 With Disposable Neb Kit Each
$71.49
$49.99

Features

Note: Prescription can be emailed or faxed to 1.203.616.2851. To email please: Click Here

More Information

  • How to Operate Your Compressor:
    NOTE: 
    Before initial operation, the nebulizer cup assembly should be cleaned following instructions described in the Cleaning
    WARNING: Before connecting the power cord, make sure the I/O (ON/OFF) switch is in the O (OFF) position. The plug is also served to disconnect the device.
  • Daily Use Operation:
    CAUTION: 
    The Compressor is designed for intermittent use only. Do not operate it continuously for more than 20 minutes for a single use without turning it off and following a cooling period for least 40 minutes
    1) Before each use inspect the Compressor and nebulizer cup assembly for damage or wear, replace as needed
    2) Place the Compressor on a table or other flat stable surface. Be sure you can easily reach the controls when seated. Do not use this device on the floor
    3) With the power switch in the O (OFF) position, plug the power cord into an appropriate electrical wall outlet
    4) Connect one end of the tubing to the compressor air-outlet connector
    5) Assemble the nebulizer cup and add indicated medication to the nebulizers cup before use
    6) Attach the other end of the tubing into the air-inlet connector found at the bottom of the nebulizer cup
    7) Turn on the Compressor by pressing the power switch to the I (ON) position and begin treatment
    8) If treatment needs to be interrupted, simply press power switch to O (OFF) position
    9) When the treatment is complete, turn off the compressor by pressing the power switch to O (OFF) position and unplug the unit from the electrical outlet
    10) Always unplug this device immediately after use
    11) DO NOT use this product in or near explosive environments, or where aerosol (spray) products are being used
    12) DO NOT pump combustible liquids or vapors with the product or use in or near an area where flammable or explosive liquids or vapors may exist
    13) DO NOT operate this product in an oxygen enriched environment, i.e. oxygen tent or oxygen hood
    14) Use only in well ventilated areas.
  • Clean After Every Use:
    - With power switch in the Off position, unplug power cord from wall outlet
    - Disconnect tubing from the air-inlet connector and set aside
    - Disassemble mouthpiece or mask from cap. Open nebulizer by turning cap counterclockwise and remove baffle
    - Wash all items, except tubing, in a hot water/dishwashing detergent solution. Rinse under hot tap water for 30 seconds to remove detergent residue. Allow to air dry
    - For reusable nebulizer only, it can be cleaned daily in dishwasher using top shelf or by following the above cleaning procedure.
  • Disinfect Daily:
    - Using a clean container or bowl, soak items in three parts hot water to one part white vinegar for 30 minutes OR use a medical bacterial-germicidal disinfectant available through your provider. Be sure to follow manufacturers instructions carefully
    - With clean hands, remove items from disinfectant solution, rinse under hot tap water, and air dry on a clean paper towel. Store in a zip-lock bag.
    - Keep the outer surface of the tubing dust-free by wiping regularly. Nebulizer tubing does not have to be washed because only filtered air passes through it
  • Compressor Cleaning:
    - With power switch in the Off  position, unplug power cord from wall outlet
    - Wipe outside of the compressor cabinet with a clean damp cloth every few days to keep dust-free
    - Do not submerge in water; doing so will result in compressor damage.
  • Filter Change:
    - Filter should be changed every 6 months or sooner if filter discolors
    - Remove filter by grasping it firmly and pulling out of the unit. Discard old filter
    - Replace with a new Drive filter. Additional filters should be purchased from your Drive provider
    - Push new filter into position.

Specification

Particulars Specifications
Power AC 120V, 60Hz
Current Max. 1.5A
Medication Capacity 5ml
Particle Size 0.5 to 10 um
MMAD 4 µm
Sound Level 60 dBA
Maximum Medication capacity 13 ml (cc)
Average Nebulization Rate = 0.18ml/min
Compressor Pressure Range 17.4 to 29 Psi (0.12 to 0.2 Mpa)
Operating Pressure Range 7.25 to 10 Psi (0.05 to 10.07 Mpa)
Liter Flow Range 5 ~ 8 lpm
Operating Temperature Range 10°C to 40°C (50°F to 104°F)
Operating Humidity Range 10% to 95% RH
Storage Temperature Range -20°C to 60°C (-4°F to 140°F)
Storage Humidity Range 10% to 95% RH
Dimension (L x W x H) 170 mm x 136 mm x 90 mm

Warranty

Limited 5 Years Warranty

Customer Reviews

Please enter your and your friends email address below.
Fields marked with * are compulsory
 
*
*
*
*


Submit Cancel
The selected product information has been successfully emailed to your friend.

Thank you for using www.shopwoundcare.com

Close